Here's some info on how this PTZ camera controller that is known by a bunch of different names
If you have any info about this controller that should be shared, please something in the comments and I'll add it in!
Contents
I. Description of performance 2
1. Introduction 2
2. Technical Data 2
II. Description of Main Functions 3
III. Installation and Connection 4
IV. Description of Keyboard Panel 5
1. Top Panel 5
2. Back Panel 6
V. LCD display and keyboard descriptions 7
VI. Keyboard Set 9
VII. Keyboard hotkey set up 10
I. Description of performance
1.
Introduction
The
controller can control PTZ cameras, up/down/left/right, zoom, focus and IRIS
(depending on camera feature compatibility) using wired RS–485 signaling. This controller can operate as many as 128
cameras within a maximal communication range of 1500 meters.
2.
Technical
Data
1. Baud rate: 1200bps, 2400bps, 4800bps, 9600bps, 19200bps, 38400bps
2. Protocol: Pelco-D, Pelco-P, SAMSUNG, PANASONIC
3. Communication: RS-485
4. Power input: DC 12V/500mA
5. Communication distance: max 1500m
6. Can control max 128 cameras
7. Password setup function
8. Ambient Temperature: 0℃~60℃
9. Relative Humidity:90%RH
10. Dimension: 205mm*168mm*48 mm
II.
Description of Main Functions
The
main functions of the keyboard include:
1. The keyboard output adopts photoelectric
insulated 485 control, which provides strong anti-interference and long-range
transmission.
2. The range for dome camera or decoder
address setup: 1~255.
3. Variable-speed operation can be applied
to the built-in dome of the high-speed dome camera.
4. Pre-set positions can be setup and
previewed in the high-speed dome camera.
5. Up to four tour routes can be setup and
previewed in the high speed dome camera, with each tour having a maximum of 16
pre-set positions, dwell time and speed for each pre-set positions
programmable.
6. The high-speed dome camera can be
manually / automatically controlled.
7. Lens zoom ratio, focus and iris can be
manually controlled.
8. More than one terminal, such as dome
cameras and decoders, can be controlled.
III. Installation and Connection
Attention: Please read the Manual carefully before installation and connection, for any incorrect cable connection may cause permanent damages to the units. Make sure power is switched off before connection and all communication cables are screened twisted pair. All communication cables should avoid high-voltage cables or other interference sources. IV. Description of Keyboard Panel
1. Top Panel
On the front panel of the keyboard are variable-speed controlling joystick, keys and LED digital displayer. The LED digital displayer shows system and operation information. The controlling joystick controls the variable-velocity movement of the dome, and manually setup positions.
2. Back Panel
Power supply outlet: connecting external DC12V power.
Communication output: RS-485 output connecting .
V.
LCD display and keyboard descriptions
1. The
LCD display shows Protocol, camera ID, Baud Rate, and Input value
PELCO D CAM=001
BR: 2400 000
①
PELCO-D : protocol is set to Pelco D
②
CAM=001 : camera ID/address is 001
③
BAUD:2400 : baud rate is 2400bps
④
INPUTS:000 : Input number or current active
button
2. 0~9 Number
·
Used for setting the camera
ID, Pre-set No. and modify the keyboard parameters.
·
When SHIFT button is activated
(“SHIFT” will be displayed in LCD) the 2,4,6,8 buttons can be used to move the
PTZ camera UP (2), DOWN (8), LEFT (4) and RIGHT (6).
3.CAM
Enter the ID (0-255) by the number key
then press CAM key: Number + CAM
The number will be displayed after item
CAM on the LCD. Change DVR number when
control DVR state.
4. CLEAR
Press key CLEAR, the Number input area
will reset.
5.CLOSE / OPEN
Under Manual mode, pressing key CLOSE and
OPEN can control the IRIS.
6. NEAR / FAR
Under Manual mode, pressing key NEAR and
FAR can control the Focus.
7.TELE / WIDE
Lens zoom for close-up image or lens zoom
for panoramic image.
8. JOYSTICK
It is 2D used to move the speed dome or
PTZ unit on pan or tilt direction. The moving speed increases as the
offset.
9. MENU
Press key MENU will open speed dome camera
mean., same Press 95
+ PRESET . Press MENU,
the LED will be light and into my factory speed dome menu.
10.TOUR
Press key TOUR mean is Press key 76
+ CALL ,Press key Tour, the LED will be light and
star to tour the multi pre-set position This press is EDIT function when control DVR state.
11.SCAN (360°pan auto
scan)
Press key TOUR mean is Press key 99
+ CALL , Press key SCAN. The LED gets turned on, and
auto scan begins.
Press key SCAN again. The LED gets turned off, and auto scan stop.
Move the Joystick to stop Auto Scan function. This press is FAN auto scan function when control DVR state.
12.PRESET
Set up the Pre-sets: Move the joystick and
adjust the Lens to select the surveillance position you need. Input No. and
then press [PRESET] key. i.e. N + PRESET Call the pre-sets:
Input the pre-set number, and press [CALL] key.
i.e. N + CALL Clear the pre-sets: Input the pre-set
number, and press [PRSET] key over 2 seconds.
i.e. N + keep to push PRESET over 2 seconds. This press is power function when control DVR state.
13.CALL
This is function for search the pre-set
position of the speed dome or receiver.
Entry the Pre-set No. in the Number area and press key CALL to call it.
i.e. N + CALL If succeed, the
number input area will reset automatically.
14. SHIFT
Press key SHIFT, it gets turned on, and
SHIFT is in effect.
Press key SHIFT again, it gets turned off,
and SHIFT is off no effect.
15.PGM
If the above action can succeed, the
number input area will reset automatically.
16.SHIFT+MENU
into keyboard menu set up.
17.AUX
AUX function 1. DVR play or PAN scan when control DVR state.
18.clear PRESET:
Number + SHIFT + CLEAR
VI. Keyboard Set
1. The
keyboard can setup different Baud rates and protocols for every camera. When
the keyboard switch dome camera/decoder addresses, it will output corresponding
controlling instructions based on the setup protocols and Baud rates. Shift + menu into keyboard
BR: 2400 000
①
CAM=001 :camera
address
②
PELCO-D :
protocol is Pelco D
③
2400 :baud
rate is 2400bps ④ 000 :input
number
PROTOCOL:PELCO-D, PELCO-P, SAMSUNG, AD, PANASONIC
BAUD
RATE: 1200, 2400, 4800, 9600, 19200, 38400 can change.
2. Password
set
PASSWORD ENABLE NO
PASSWORD ENABLE: NO :no password required
PASSWORD ENABLE: YES :display “OK” password have used.
PASSWORD: **** :
First password is 0000, user can set new
password, password is 4
number. setting later press [ PGM ] is save and exit .
3. Keyboard
Control mode
MODE →2D
INITIAL: NO
MODE 2D: only keyboard control dome.
MODE 3D / 2D-M: keyboard and DVR
parallel connection control dome.
4. Keyboard
initial
MODE 2D
INITIAL: →NO
INITIAL: NO: the
keyboard initial is close.
INITIAL: YES→OK the keyboard initial is open. initial
later the keyboard setting is address 1 , baud rate 2400bps ;, protocol Pelco D .
VII.
Keyboard hotkey set up
l
Enter “12” then press PGM to select Baud Rate to 1200 bps.
l
Input “24” then press PGM to select Baud Rate to 2400 bps.
l
Input “48” then press PGM to select Baud Rate to 4800 bps.
l
Input “96” then press PGM to select Baud Rate to 9600 bps.
l
Input “192” then press PGM to select Baud Rate to 19200 bps.
l
Input “384” then press PGM to select Baud Rate to 38400 bps.
l
Input “44” then press PGM to select Pelco–D protocol.
l
Input “50” then press PGM to select Pelco–P protocol.
l Input “999” then press AUX to disable/enable beep
Untested functions.
- 990 aux s-l:
- 991 aux lock
- 1-4 AUX = Aux ON/OFF
No comments:
Post a Comment
Feel free to leave a comment! If you have any information that you think should be included, please do so here and I'll get it added in.