Wednesday, December 22, 2021

VAP102 JSK-8003H camera PTZ controller

Here's some info on how this PTZ camera controller that is known by a bunch of different names



If you have any info about this controller that should be shared, please something in the comments and I'll add it in!

Contents


I. Description of performance 2

1. Introduction 2

2. Technical Data 2

II. Description of Main Functions 3

III. Installation and Connection 4

IV. Description of Keyboard Panel 5

1. Top Panel 5

2. Back Panel 6

V. LCD display and keyboard descriptions 7

VI. Keyboard Set 9

VII. Keyboard hotkey set up 10

I. Description of performance

 

1.   Introduction 

 

The controller can control PTZ cameras, up/down/left/right, zoom, focus and IRIS (depending on camera feature compatibility) using wired RS–485 signaling.  This controller can operate as many as 128 cameras within a maximal communication range of 1500 meters. 

 

2.   Technical Data

 

1.     Baud rate: 1200bps2400bps4800bps9600bps, 19200bps, 38400bps

2.     ProtocolPelco-D, Pelco-P, SAMSUNG, PANASONIC

3.     Communication: RS-485

4.     Power input: DC 12V/500mA

5.     Communication distance: max 1500m

6.     Can control max 128 cameras

7.     Password setup function

8.     Ambient Temperature: 0~60

9.     Relative Humidity90%RH

10. Dimension: 205mm168mm48 mm

 


 

II. Description of Main Functions

The main functions of the keyboard include: 

1.  The keyboard output adopts photoelectric insulated 485 control, which provides strong anti-interference and long-range transmission. 

2.  The range for dome camera or decoder address setup: 1~255.

3.  Variable-speed operation can be applied to the built-in dome of the high-speed dome camera. 

4.  Pre-set positions can be setup and previewed in the high-speed dome camera. 

5.  Up to four tour routes can be setup and previewed in the high speed dome camera, with each tour having a maximum of 16 pre-set positions, dwell time and speed for each pre-set positions programmable. 

6.  The high-speed dome camera can be manually / automatically controlled.

7.  Lens zoom ratio, focus and iris can be manually controlled. 

8.  More than one terminal, such as dome cameras and decoders, can be controlled.

 


 

III. Installation and Connection

Attention: Please read the Manual carefully before installation and connection, for any incorrect cable connection may cause permanent damages to the units. Make sure power is switched off before connection and all communication cables are screened twisted pair. All communication cables should avoid high-voltage cables or other interference sources. IV. Description of Keyboard Panel  

 

1. Top Panel 

On the front panel of the keyboard are variable-speed controlling joystick, keys and LED digital displayer. The LED digital displayer shows system and operation information. The controlling joystick controls the variable-velocity movement of the dome, and manually setup positions. 

 


 

 

 

2. Back Panel 

 

 


 

 

Power supply outlet: connecting external DC12V power. 

Communication output: RS-485 output connecting . 



 

V. LCD display and keyboard descriptions 

 

1.    The LCD display shows Protocol, camera ID, Baud Rate, and Input value

 

PELCO D                 CAM=001

BR: 2400                     000

            PELCO-D                  : protocol is set to Pelco D

            CAM=001                  : camera ID/address  is 001

            BAUD2400            : baud rate is 2400bps

            INPUTS000           : Input number or current active button

 

2. 0~9 Number

·         Used for setting the camera ID, Pre-set No. and modify the keyboard parameters.

·         When SHIFT button is activated (“SHIFT” will be displayed in LCD) the 2,4,6,8 buttons can be used to move the PTZ camera UP (2), DOWN (8), LEFT (4) and RIGHT (6).

 

3.CAM 

Enter the ID (0-255) by the number key then press CAM key:  Number   +  CAM

The number will be displayed after item CAM on the LCD.  Change DVR number when control DVR state.

 

4. CLEAR

Press key CLEAR, the Number input area will reset.

 

5.CLOSE / OPEN

Under Manual mode, pressing key CLOSE and OPEN can control the IRIS. 

 

6. NEAR / FAR

Under Manual mode, pressing key NEAR and FAR can control the Focus.

 

7.TELE / WIDE

Lens zoom for close-up image or lens zoom for panoramic image.

 

8.   JOYSTICK

It is 2D used to move the speed dome or PTZ unit on pan or tilt direction. The moving speed increases as the offset. 

 

9.   MENU

Press key MENU will open speed dome camera mean., same Press  95   +  PRESET  . Press MENU, the LED will be light and into my factory speed dome menu.

 

10.TOUR

Press key TOUR mean is Press key 76   + CALL  ,Press key Tour, the LED will be light and star to tour the multi pre-set position This press is EDIT function when control DVR state.

 

11.SCAN (360°pan auto scan)

Press key TOUR mean is Press key 99   + CALL  , Press key SCAN. The LED gets turned on, and auto scan begins.

Press key SCAN again.  The LED gets turned off, and auto scan stop. Move the Joystick to stop Auto Scan function. This press is FAN auto scan function when control DVR state.

 

12.PRESET 

Set up the Pre-sets: Move the joystick and adjust the Lens to select the surveillance position you need. Input No. and then press [PRESET] key.  i.e. N  +  PRESET Call the pre-sets: Input the pre-set number, and press [CALL] key.  i.e. N  +  CALL Clear the pre-sets: Input the pre-set number, and press [PRSET] key over 2 seconds.  i.e. N  + keep to push  PRESET  over 2 seconds.  This press is power function when control DVR state.

 

13.CALL 

This is function for search the pre-set position of the speed dome or receiver.  Entry the Pre-set No. in the Number area and press key CALL to call it. i.e. N  +  CALL If succeed, the number input area will reset automatically. 

 

14. SHIFT 

Press key SHIFT, it gets turned on, and SHIFT is in effect.

Press key SHIFT again, it gets turned off, and SHIFT is off no effect.

 

15.PGM

If the above action can succeed, the number input area will reset automatically.

 

16.SHIFT+MENU

into keyboard menu set up.

 

17.AUX

AUX function 1.  DVR play or PAN scan when control DVR state.

 

18.clear PRESET:

 Number  + SHIFT + CLEAR 

 

VI. Keyboard Set 

 

1.    The keyboard can setup different Baud rates and protocols for every camera. When the keyboard switch dome camera/decoder addresses, it will output corresponding controlling instructions based on the setup protocols and Baud rates.  Shift + menu into keyboard 

 PELCO  D                 CAM=001

BR: 2400                     000                                 

 

            CAM=001    camera address

            PELCO-D    :  protocol is Pelco D

            2400         baud rate is 2400bps 000          input number 


PROTOCOL
PELCO-D, PELCO-P, SAMSUNG, AD, PANASONIC

BAUD RATE: 1200, 2400, 4800, 9600, 19200, 38400 can change.

2.  Password set

PASSWORD    ENABLE NO

PASSWORD ENABLE: NO no password required

PASSWORD ENABLE: YES display “OK” password have used.

PASSWORD **** First password is 0000, user can set new

password, password is 4 number. setting later press [ PGM ] is save and exit .

 

3.  Keyboard Control mode  

MODE     →2D
INITIAL:    NO

MODE  2D:   only keyboard control dome.
MODE  3D / 2D-M: keyboard and DVR parallel connection control dome.

4.  Keyboard initial 

MODE       2D
INITIAL:    →NO

 

INITIAL:     NO:                 the keyboard initial is close.
INITIAL:     YESOK        the keyboard initial is open. initial later the keyboard setting is address 1 , baud rate  2400bps ;, protocol  Pelco D .

VII. Keyboard hotkey set up

l   Enter “12” then press PGM to select Baud Rate to 1200 bps.

l   Input “24” then press PGM to select Baud Rate to 2400 bps.

l   Input “48” then press PGM to select Baud Rate to 4800 bps.

l   Input “96” then press PGM to select Baud Rate to 9600 bps.

l   Input “192” then press PGM to select Baud Rate to 19200 bps.

l   Input “384” then press PGM to select Baud Rate to 38400 bps.

l   Input “44” then press PGM to select Pelco–D protocol.

l   Input “50” then press PGM to select Pelco–P protocol.

l   Input “999” then press AUX to disable/enable beep 

Untested functions.

  • 990 aux s-l:
  • 991 aux lock
  • 1-4 AUX = Aux ON/OFF


No comments:

Post a Comment

Feel free to leave a comment! If you have any information that you think should be included, please do so here and I'll get it added in.