Thursday, July 14, 2016

AudioCodes MP-112 or MP-124 factory reset

Here's how to reset both an AudioCodes MP-112 or MP-124 FXS adapter.  Probably works with
other models.

OR

How to find out the IP of the unit (or really most any ethernet device) without resetting, which is described a little bit below.

Hardware Reset:
Power up the unit.  If first time the fail light might be lit, it normally clears itself out after 2 minutes or so.

While unit is powered on do the following:

1. Press and hold the RESET on the back of the unit for 10 seconds.  Use a paperclip or some small pokey thing to do this.

2. Waiting For\
> MP112 for the fail light to go out (after about a 2 minutes)

> MP-124 "READY" light to go green

3. Plug in the Ethernet cable, unit should be HTTP accessible on the default IP of  10.1.10.10

#####################################################################
http://10.1.10.10
users/password is  "Admin/Admin"  (case sensitive, note the CAPITAL "A"!!!!!!!!)
#####################################################################

When you set the IP, at least on the MP124, you must click on "SUBMIT" then http to the new IP and select "BURN". 

DISCOVER the IP OF THE BOX WireShark

IF you can't find the IP of the box (or you dont want to reset it to factory)
1.  (Install) start wireshark

2.  Connect the audiocodes directly to your computer and start a capture in wireshark of the ethernet port.

3. plug the audiocodes directly into your computer.  It doesn't matter what IP your computer has either.

4  unplug the power to the audiocodes and plug it back in.

5. watch the shark log.  What you are looking for under the "SOURCE" column is AudioCodes, or some close name to that.

6. when you spot it, on the right side under "INFO" for those entries you see entries like "Who is x.x.x.x? Tell X.X.X.X"


you might have but don't know the IP to.